A permit-required confined space entry is authorised on a document, not on a decision. Paragraph (f) of 29 CFR 1910.146 lists fifteen items the entry permit has to identify. Audits rarely fail on an empty box; they fail on the links between a reading, a name and a time.
The fifteen items, block by block
| Block | Items in (f) | What it fixes on paper | Where it usually breaks |
|---|---|---|---|
| Space and job | (1)–(3) | which space, why, how long the permit runs | duration copied from the previous permit |
| People | (4)–(6) | who is inside, who is watching, who authorised | roster written at shift start, never updated |
| Hazards and controls | (7)–(9) | what is dangerous, how it was isolated, what “acceptable” means | acceptable conditions described in words, without thresholds |
| Readings and response | (10)–(13) | test results with testers and times, rescue, communication, equipment | one set of numbers entered at the end of the shift |
| Site-specific and linked permits | (14)–(15) | anything this space demands, plus hot work and similar permits | hot work referenced but not attached |
The first block is administrative and easy to get right. The second is where a permit stops describing the entry and starts describing the shift that was planned. (f)(4) asks for the people inside “by name or by such other means… as will enable the attendant to determine quickly and accurately, for the duration of the permit, which authorized entrants are inside”. The note to that item allows a roster or a tracking system, provided the permit says which one is in use. A roster that is not reconciled when two contractors swap places at lunch is not a tracking system.
Block three is the one an auditor reads most slowly. (f)(9) is “the acceptable entry conditions”, and conditions written as “atmosphere tested safe” leave nothing to check. They need the thresholds the test is judged against — the hazardous-atmosphere definition in (b), where flammable gas or vapour above 10 percent of its lower flammable limit, oxygen below 19.5 or above 23.5 percent, any substance above its exposure limit, and anything immediately dangerous to life or health all count.
Block four is where monitoring work either lands on the permit or evaporates.
The three items that carry the readings
(f)(10) is the load-bearing one: “the results of initial and periodic tests performed under paragraph (d)(5)… accompanied by the names or initials of the testers and by an indication of when the tests were performed.” Three facts per reading — value, tester, time — and the plural matters, because (d)(5)(ii) requires testing or monitoring during the entry to confirm acceptable entry conditions are being maintained. A shift produces a series, not a number.
(f)(3) sets the window that series belongs to: the date and the authorised duration, which (e)(4) limits to the time the task actually needs.
(f)(12) closes the loop with the communication procedures entrants and attendants use to maintain contact. A reading that alarms inside the space has to travel along that procedure.
Written down by hand at the end of the shift, the timestamps are approximate and the initials belong to whoever holds the pen. That is not a compliance verdict — (e)(3) is satisfied by a posted sheet — but the record has stopped being evidence and become a summary.
What the readings have to be, before and during
(d)(5)(i) requires a test to establish acceptable entry conditions before entry is authorised. Where isolation is infeasible because the space is large or part of a continuous system such as a sewer, pre-entry testing applies to the extent feasible and the areas where people work are then monitored continuously.
The order is fixed by (d)(5)(iii): oxygen first, then combustible gases and vapours, then toxic gases and vapours. It is not ceremonial. A catalytic combustible sensor needs oxygen to read, so a combustible reading taken in air that has already been displaced is a number without meaning.
(d)(5)(iv) gives each entrant, or their representative, the opportunity to observe pre-entry and subsequent testing — easier to honour when the reading is visible at the entry point rather than on a screen inside the space.
And where a site reaches entry through the reclassification path, (c)(5)(ii)(C) requires a calibrated direct-reading instrument for the testing that supports it. A fresh-air zero is not a span calibration.
After the signature
(e)(2) puts authorisation on a named person: before entry begins, the entry supervisor identified on the permit signs it.
(e)(4) caps the duration at the time the task needs. (e)(5) requires the supervisor to terminate entry and cancel the permit when the work is complete, or when a condition that is not allowed under the permit arises in or near the space — the second half is what turns a reading into an action. (e)(6) retains every cancelled permit for at least 1 year, with any problems encountered during the entry noted on the permit itself, so the programme review under (d)(14) has something to read. A permit that records the plan and never the deviation makes that review a formality.
A ten-minute review before the shift
- Does (f)(9) carry thresholds, or adjectives?
- Does (f)(4) name the tracking method, and does the attendant reconcile it during the entry?
- Does (f)(10) have room for a series of readings with tester and time — or one line for “results”?
- Is (f)(11) a number someone has actually called this year?
- Does (f)(3) match the job in (f)(2), or last week's job?
- After cancellation, where does the deviation get written?
Where the readings are captured by the monitoring equipment, those questions get shorter. Our station keeps atmosphere records, entrant logs, attendant records and alarm history with timestamps, and holds entry until a permit is approved, so the record is assembled while the work happens. The attendant's own duties are set out in what the attendant role covers; how many points a space needs is a separate calculation, covered in how many sampling points a space needs.
Questions buyers ask
How many items must a permit-required confined space entry permit
contain?
Fifteen, in 1910.146(f)(1) through (f)(15), from the space and purpose to any linked hot
work permit. Appendix D to the standard gives example permits whose elements are considered
to comply.
Can the entry permit be electronic?
The standard sets no format. (e)(3) requires the completed permit to be available to
entrants at the entry portal or by any other equally effective means, and the note to
(f)(4) expressly allows a roster or tracking system in place of a name list. An electronic
permit answers the same three questions: is it available at the entry, does it show who is
inside now, and is it retained after cancellation.
How long are cancelled permits kept?
At least 1 year, under (e)(6), with any problems noted on the permit. Retention exists to
feed the programme review in (d)(14), which may be run once a year across all entries.
About Yunku Technology
Yunku Technology builds confined space monitoring stations that tie the atmosphere record, the entrant log and the permit workflow to one timestamped source, with alarm logic running at the edge so a dropped uplink does not silence a local alarm. The station monitors and alarms; ventilation, rescue and the attendant's judgement stay with people. Configuration and specifications are on the confined space monitoring station page.