Ship enclosed spaces: CO2 joins the five-gas pre-entry test

The pre-entry atmosphere test for enclosed spaces is expanding from four gases to five, with carbon dioxide now mandatory. The configuration advice: verify detection parameters, certificates and sampling method first — a full replacement is usually not necessary.

With IMO resolution MSC.581(110) in force, the mandatory pre-entry test for enclosed spaces expands from oxygen, flammable gas, carbon monoxide and hydrogen sulphide to five gases, with carbon dioxide added as a required reading. Yunku Technology's advice for ship confined space monitoring equipment: check the parameters first, then certificates and sampling method.

Why a four-gas detector is no longer enough

Traditional tank-entry checks watch four parameters: oxygen (acceptable range 19.5%-23.5%), flammable gas (below 1% of the lower explosive limit), carbon monoxide and hydrogen sulphide. Cargo residue fermentation and firefighting-system leaks both let carbon dioxide accumulate in the bilge, and a four-gas test misses that suffocation risk. MSC.1/Circ.1477 also requires the pre-entry detector to have remote sampling capability — a diffusion sensor worn on the body cannot substitute for it.

Which compartments are tested to five parameters

Cargo holds, ballast tanks, fuel tanks, sewage tanks, pump rooms, machinery-space bilges, double bottoms and cofferdams are all enclosed spaces that must show five-parameter readings before entry; ships carrying gas-generating cargoes need additional portable detectors matched to the vessel type. GB/T 40531.1-2021 sets the corresponding performance, alarm-grading and protection requirements for marine portable gas detectors, so selection can go straight off the table.

Does the equipment need replacing? Four checks first

First, detection channels: can the existing unit be extended with a CO2 parameter? Have the manufacturer confirm channels and range in writing before any retrofit — the gas-detection module of the Yunku LSM3000 series confined space monitoring station supports extending detection parameters by industry. Second, class certification: portable units need a CCS marine product certificate; equipment without complete certification does not go on board. Third, sampling: a pump type with an extension tube reaches the dead corners at the bottom of a tank, while a diffusion type only reads around the sensor. Fourth, records: pre-entry readings and continuous in-work logging must be exportable by voyage, so they match the permit during marine inspections.