Confined space gas detector: 4-gas, pumped or diffusion?

A confined space gas detector is specified in two decisions, in this order: which channels the space demands, then how the sample reaches the sensor. A four-gas diffusion unit suits a shallow sump and misleads in a six-metre manhole. The difference is sample point and response time.

A confined space gas detector is specified in two decisions, in this order: which channels the space demands, then how the sample reaches the sensor. A four-gas diffusion unit suits a shallow sump and misleads in a six-metre manhole. The difference is sample point and response time.

What “four-gas” covers, and what it does not

The four channels most instruments ship with are oxygen, carbon monoxide, hydrogen sulfide and combustible gas (LEL). That set is an instrument-market convention, not a regulatory list. The standard defines a hazardous atmosphere instead: flammable gas or vapour above 10 percent of its lower flammable limit, oxygen below 19.5 or above 23.5 percent, any substance above its exposure limit, and any other condition immediately dangerous to life or health (29 CFR 1910.146(b)).

For ordinary pits, sewers and tanks the four channels cover most of what kills: oxygen displaced by decay or purging, methane and solvent vapour inside the flammable range, hydrogen sulfide from organic load, carbon monoxide from engines and hot work. Paragraph (d)(5)(iii) also fixes the testing order — oxygen, then combustible gas, then toxic gas — worth keeping, because a catalytic combustible reading is unreliable in oxygen-deficient air.

What the package cannot read is the space's own chemistry. A solvent store needs ppm-level VOC, which is a photoionisation detector rather than an LEL bead. A fermenter, grain silo or heavily loaded sewer produces carbon dioxide, measured by infrared. Ammonia, chlorine and sulphur dioxide each need their own electrochemical cell, and welding adds nitrogen dioxide and ozone. Build the channel list from what is stored, what decays and what the work produces, then confirm a multi gas detector can host those cells and show them at the entry point.

Diffusion, pumped, or fixed at the workface

Diffusion. The sensor is open to the air and reads where the instrument stands, settling in tens of seconds. Worn by the entrant it protects the breathing zone, which is its job. Held at the opening it is a legitimate spot check. Lowered into a tank on a rope it becomes something else: read while moving, it describes the air it has just passed through, not the stratum it hangs in. Lowering it and waiting at each level works, if the wait is long enough.

Pumped sampling. A pump pulls air from a defined point through a line, which is how the bottom of a manhole is tested without entering it. The cost is lag, and the lag is physical. Our integrated detector draws 0.6–1 L/min through up to 8 m of hose; 8 m of 4 mm bore holds roughly 0.1 L, so six to ten seconds go into clearing the line before the sensor sees the sample, plus a published response of ≤25 s and ≤25 min stabilisation from cold start. A reading taken as the pump starts is the previous location's air. Purge between levels, and count filters and water traps as part of the sample path.

Fixed at the workface. During the entry the reading has to be where the work is and where the attendant stands. A pump-suction unit at the workface linked to a display at the entry point does both, and stops anyone leaning into the opening to read a screen inside.

Choosing by space geometry

Space and accessPre-entry testDuring entryChannels to check
Sump or pit, side access, under 1.2 m diffusion hand-held at the opening diffusion unit worn by the entrant O₂, LEL, H₂S, CO
Manhole over 3 m, vertical descent pumped with hose; opening, mid-depth, bottom pump-suction at the workface plus a unit on the entrant add CO₂ where organic load is heavy
Tank, hatch above, stratification likely pumped from the hatch; upper and lower levels separately pump-suction at the workface infrared LEL where solvents or inerting apply; add PID for VOC
Tunnel or gallery, tens of metres pumped readings along the run fixed nodes on a local radio link add NO₂ where engines run inside
Space with hot work inside pumped before entry and after each pause continuous, second unit near the hot work add NO₂ and O₃; CO cell regardless

A row here is a starting point, not a hazard assessment. How many sampling points a space needs is a separate calculation, covered in our note on how many sampling points a space needs; ventilation time before the test is set out in how long ventilation should run.

Three things that quieten a reading

Line condition. A saturated trap, kinked hose or wet filter still passes air — not the air you think, and it under-reads hydrogen sulfide worst. Do not test through a line that has sat in a wet well all week.

Sensor limits and poisoning. A catalytic bead needs oxygen to burn the sample, so it under-reads in inerted or oxygen-deficient air, and it is poisoned by silicones, sulphur compounds and leaded vapour: a tank just lined can show a clean LEL from a bead that stopped responding. Infrared reads hydrocarbons without oxygen but not hydrogen. Cross-sensitivity runs both ways — high hydrogen sulfide can drive a CO cell positive and raise an alarm that has nothing to do with CO.

Calibration. 1910.146(c)(5)(ii)(C) requires testing before entry with a calibrated direct-reading instrument, and a fresh-air zero is not a span calibration. A bump test shows the sensor responds; the span interval comes from the manufacturer and your own history. Recalibrating a poisoned sensor until it agrees with the cylinder hides the fault instead of fixing it.

What to write into the purchase specification

  • The channel list with extra cells named, and confirmation that those channels display at the entry point, not on a laptop afterwards.
  • Sampling method, hose length and pump flow, which set how long a pre-entry test takes and how many levels one operator covers.
  • The alarm path at the workface, at the entry point and to a remote supervisor, plus what happens locally when the uplink drops.
  • Readings with timestamps that can sit beside the permit; (d)(5)(iv) gives entrants the right to observe testing, and a stamped record keeps that visible afterwards.

Questions buyers ask

Is a four-gas detector enough for any confined space?
For the usual asphyxiant and flammable hazards in pits, sewers and utility chambers, yes. For the space's own chemistry — ppm solvent vapour, carbon dioxide, ammonia, chlorine, welding fume — no. The instrument is chosen after the hazard assessment, not instead of it.

Can a six-metre manhole be tested by lowering a diffusion detector on a rope?
It can work if the unit stops and stabilises at each depth with a long enough wait. A pumped unit with a hose is cleaner: the sample point is the end of the hose, the operator stays outside, and the reading describes one location.

How often does a confined space gas detector need calibrating?
The span interval comes from the manufacturer and your programme's history; a bump test before use checks response and alarm. Entry requires a calibrated instrument, so the interval must keep it inside calibration on every working day.

About Yunku Technology

Yunku Technology builds confined space monitoring stations around a pump-suction gas detector: oxygen, carbon monoxide, hydrogen sulfide and combustible gas as standard, other cells specified per site, Ex ia IIC T4 Gb in the detector and Ex ib IIC T4 Gb in the station. Readings, alarms, headcount and entrant vital signs reach the entry point and the remote supervisor together, and alarm logic runs at the edge so a dropped uplink does not silence a local alarm. Configuration and specifications are on the confined space monitoring station page.